Inspection Status: Approved
Inspection History: PLUMBING - FINAL
Permit Number - T06CM02999
Inspection Description - PLUMBING - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
06/26/2006 | PLUMBING - FINAL | Approved | IVRS - Inspection :* | |
06/22/2006 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* INSTALL CENTER CLIP IN FRONT OF SINK, CAULK FRONT OF SINK. |
|
06/19/2006 | PLUMBING - FINAL | Partial Approval | IVRS - Inspection :* WH OK INSTALL CABINETS IN A MANNER THAT WILL FACILITATE REMOVAL OF WH IF NECESSARY. RECALL AFTER KIT SINK IS INSTALLED. |
|
06/13/2006 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* PROVIDE: 1. EXPANSION CONTROL IF WATER SUPPLY HAS A BACKFLOW PREVENTER - DISREGARD IF NOT APPLICABLE. - FLEX CONNECTOR NOT ACCEPTED ON T&P DRAIN. - FULL PORT SHUT OFF VALVE REQUIRED - EXPOSE EXISTING CLEAN OUT ON KIT. SINK DRAIN - INSTALL KIT. SINK. |
|
06/02/2006 | PLUMBING - FINAL | Cancelled | IVRS - RI canceled |