Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: BUILDING - FINAL
Permit Number - T06CM02998
Inspection Description - BUILDING - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
12/06/2006 | BUILDING - FINAL | Approved | IVRS - Inspection :* | |
12/05/2006 | BUILDING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) NEED ALL SPECIAL CERTS |
|
12/01/2006 | BUILDING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) WEEP SCREED WEST SIDE OF HOUSE NEEDS CLEARANCE FROM FINAL GRADE 2) RECEPTACLE PLATE COVER MISSING BATHROOM 3) RECEPTACLE NOT COMPLETED IN LAUNDRY ROOM 4) W/H NOT WIRED 5) NEED ADDRESS IDENTIFICATION ON POWER PANEL 6) HEAT PUMP NEEDS TO BE MARKED FOR MODEL IDENTIFICATION 7) NEED A STOVE AT FINAL 8) MECHANICAL DUCT NEEDS TO BE MOVED FOR CLEARANCE IN ATTIC OPENING 9) NO ACCESS INTO ATTIC 10) RECEPTACLE UNDER SINK NOT IN BOX 11) WIRE FOR RANGE HOOD RUNNING WILD, NO BOX 12) MISSING RECEPTACLE EAST SIDE OF HALLWAY 13) NO POWER TO RECEPTACLES BEDROOM #3 14) MASTER BEDROOM NEEDS RECEPTACLE 6" FROM DOOR ENTRY |