Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
Permit Number - T06CM02947
Inspection Description - PLUMBING - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
05/23/2007 | PLUMBING - FINAL | Approved | IVRS - Inspection :* | |
05/21/2007 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* 1. ALL HOSE BIBS SHALL HAVE VACUUM BREAKERS 2. EXTERIOR BUILDING SEWER CLEANOUT TO BE PROPERLY TERMINATED AT GRADE & BE SEWER GAS TIGHT. 3. STOOL FLUSH HANDLE TO BE TO WIDE SIDE OF RESTROOM AREA. 4. NEW LAVS REQUIRE HOT WATER TO HAVE SOME FORM OF DEVICE TO LIMIT HOT WATER TEMPERATURE BESIDES WATER HEATER. 5. WATER HEATER TO HAVE NO BLACK IRON FITTINGS, SHALL HAVE APPROVED WATER PIPING MATERIALS. 6. PLEASE EXPOSE CLEANOUT FOR SINK IN HALL. 7. EXPOSE WATER HEATER T&P TERMINATION. |