Inspection History Details
Inspection Status: Approved
Inspection History: STUCCO MESH
Permit Number - T06CM02934
Inspection Description - STUCCO MESH
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/26/2006 | STUCCO MESH | Approved | IVRS - Inspection :* | |
| 07/13/2006 | STUCCO MESH | Partial Approval | IVRS - Inspection :* 1) WIRE SIZES FOR A/C AND FURNACE AT FINAL-WILL INSPECT PER U.L. LABEL EQUIPMENT MINIMUM CLR. AMP AND BREAKER SIZE. CHECK WIRE SIZES-THEY ARE NOT PER PLAN 2) TAPE DRYER DUCT 3) OK TO INSULATE |
|
| 07/10/2006 | STUCCO MESH | Partial Approval | IVRS - Inspection :* 1) NEED H20 TEST, DWV/H20 POTABLE, PROTECT PEX SEE MARK ON FLOOR 2) ITEM 03050 NOT REQUIRED-ALL ELECTRIC 3) H.D.'S REQUIRE SPECIFIC BOLTS, NAIL SIZE-SEE PLAN 4) CUT NAIL PLATE TO FLOOR MARKED 5) BLK AT CONDENSATE GARAGE 6) BLK SIDES OF SHOWER, MASTER SCREW SURROUND HALL BATH 7) NOTCH T/PLATE NON-BEARING TRUSSES, NEAR ENTRY 8) RECEPT TO BE 1' FROM TOP OF BAR TOP OR REMOVE 9) NEED SHEAR TRANSFER FOR AT #2 SHEAR 3 PT BEARING 10) ATTACH TOP PLATE PER 10/DT1 SHEAR 11) MOVE OR REMOVE RECEPT AT SHORT KITCHEN WALL 12) PLAN NOT NOTED FOR ELECTRIC FURNACE HOME RUN WIRE SIZE 13) A/C CIRCUIT ON PLAN TO BE #6-60 AMP |