Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/04/2007 | PLUMBING - FINAL | Approved | IVRS - Inspection :* | |
| 05/25/2007 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* CORRECT THE FOLLOWING ITEMS: 1. SECURE DW HOSE 2. PROVIDE CLEANOUTS AT KIT. SINKS AND LAUNDRY 3. SEAL ROOF PENETRATIONS W/FLASHINGS 4. HAMMER ARRESTORS REQUIRED AT LAUNDRY 5. COVER OR INSTALL CAST IRON AT EXPOSED ABS FITTINGS AT LAUNDRY. 6. DRAINAGE FITTINGS REQUIRED ON VENTS BELOW FLOOD LEVEL OF KIT. SINK 7. CAULK WCS AT CONTACT TO FLOOR 8. SADDLE TAPS ARE NOT CODE APPROVED FITTINGS. INSTALL UPC APPROVED VALVES. 9. HB VAC BREAKERS 10. SUPPORT ON B VENTS 11. COMBUSTION AIR AT FURNACE 12. WATER HEATER INSTALLED ON WOOD PLATFORM REQUIRES DRAIN PAN. |
|
| 05/22/2007 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* HB MISSING VAC BREAKER INSP STOPPED COMPLETE WORK THEN CALL FOR INSP. |
|
| 05/15/2007 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* 1. PROVIDE NEW GAUGE 2. LIST NOT COMPLETE |