Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - INTERMEDIATE
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 02/20/2007 | PLUMBING - INTERMEDIATE | Approved | IVRS - Inspection :* | |
| 02/13/2007 | PLUMBING - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. PROVIDE A PRESSURE TEST ON GAS PIPING. 2. PROVIDE SWEEPS AT 90 DEG. CHANGES OF DIRECTION ON LAV WASTE. 3. PROVIDE WATER TEST THRU ROOF ON WASTE & VENT. 4. PROVIDE TEST ON TUB OVERFLOW GASKET BY INSTALLING PLUG AND FILLING SECOND STORY TUB TO OVER FLOW LEVEL. 5. CAP OLD KIT DRAIN PIPING W/PIPE CAP OR PLUG. 6. TYPE M COPPER NOT APPROVED FOR OUTDOORS. |
|
| 02/01/2007 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* 1) UNIT #2 TEST ON TUB DRAIN PIPING IS OK 2) TEST TUB WASTE AND OVERFLOW GASKETS BY FILLING TUB TO FLOOD LEVEL 3) SUPPORT PIPING WITH APPROVED PIPE SUPPORTS NOT P TAPE 4) REMOVE EXCESS FLUX FROM SOLDIER JOINTS 5) USE APPROVED DRAINAGE FITTINGS ON LAV-I WILL ACCEPT EXISTING PIPING IF IT WILL HOLD A WATER TEST THRU ROOF |
|
| 01/31/2007 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* |