Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/04/2007 | ELECTRIC - FINAL | Approved | IVRS - Inspection :* OK UNIT #2 |
|
| 05/25/2007 | ELECTRIC - FINAL | Partial Approval | IVRS - Inspection :* #2 1. PROTECT BULB IN CLOSET UPSTAIRS 2. PROTECT ROMEX CLOSET/STORAGE - AT STAIRS OK UNIT #1 |
|
| 05/22/2007 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* UNIT #1 RECEPTACLE IN LIVING ROOM NORTH OF CURTAIN (WHERE SHEETROCK MUD BOX IS) IS SHOWING AN OPEN GROUND. ALSO, COVER OR SEAL TOP OF WASHER RECEPTACLE OUTSIDE AT WASHER IT'S OPEN AND WATER CAN GET INSIDE. UNIT #2 LAST INSPECTION REQUESTED OPEN WIRING TO BE PROTECTED 2ND FLOOR SOUTH STORAGE ROOM |
|
| 05/15/2007 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* #2 1. ROMEX IN WH ROOM TO BE PROTECTED, J-BOX MISSING COVER 2. 2ND FLOOR CLOSET PROTECT ROMEX 3. 2ND FLOOR STORAGE ROOM J-BOX OPEN WIRING #1 1. OPEN J-BOX ABOVE RANGE 2. RECEPTACLES IN LIVING ROOM NOT ENERGIZED ALL CIRCUITS ON 3. FRONT O/S LIGHT DOES NOT COME ON |
|
| 01/26/2007 | ELECTRIC - FINAL | Partial Approval | IVRS - Inspection :* 1. SUPPORT CABLES ABOVE PANELS WITHIN 12" 2. HAVE BUILDING INSPECTOR VERIFY HOLES IN JOIST OK ROUGH ELECTRIC SUBJECT TO OTHER INSPECTORS *NOTE: ARC FAULT REQUIREMENTS 210.12 |