Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T06CM02887

Parcel: 113101320


Addresses:

1709 E SILVER ST


Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Permit Number - T06CM02887

Inspection Description - EXT METAL CLIPS/EXT SHEATHING

Inspection Status - Approved

Date Description Inspector Results Comments
02/05/2007 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
01/31/2007 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) PER DETAIL 5/S201 DBL KING STUDS
2) COMPLETE PORCH HARDWARE
3) SUBMIT AS BUILT FOR NEW DINING ROOM PRIOR TO INTERMEDIATES
4) COMPLY WITH NOTES 5 AND 6 FROM PREVIOUS
5) APPROVED PLAN CALLS FOR UNDERGROUND SERVICE WAIVER REQUIRED FOR OVERHEAD FROM BLDG OFFICIAL
01/30/2007 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) CLIP STUDS TO PLATES AT BEARING WALLS
2) TIE BEAMS TO POSTS/POST TO PLATE
3) HANGERS REQUIRED AT HIP JACKS
4) SQUASH BLOCKS NEEDED AT TJI'S
10/13/2006 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) SUBMIT AS BUILT FOR NEW GLUE LAM AND 2 X 6 JOSTS IN EXISTING KITCHEN NOT ON PLAN
2) FRONT PORCH NOT COMPLETE
3) PER DETAIL 4/S201 CC66 POST CAPS MISSING REAR PORCH
4) PER DETAIL 3/S201 KEYNOTE 8 A35 EACH TRUSS
5) BLOCK AND NAIL ALL JOINTS AT BRACED PANELS WITH 2 AB'S EACH PANEL
6) SUBMIT AS BUILTS FOR ALL WORK NOT ON PLAN
7) STOPPED INSPECTION