Date Description Inspector Results Comments
10/18/2006 PLUMBING - ROUGH, SOIL Approved IVRS - Inspection :*
10/16/2006 PLUMBING - ROUGH, SOIL Not ready for Inspection IVRS - Inspection :*
1. ABS MAY NOT BE TESTED WITH AIR.
2. ALL BRANCH PIPING AND UPPER TERMINAL CLEAN OUT TO BE FULL SIZE.
10/13/2006 PLUMBING - ROUGH, SOIL Denied IVRS - Inspection :
See detailed listing on site.| 999*
SOME AREAS FLAT, SOME BACKPITCH OTHERS 1/8"
PROVIDE 2% FALL UNLESS SPECIFICALLY NOTED ON PLAN.
10/12/2006 PLUMBING - ROUGH, SOIL Not ready for Inspection IVRS - Inspection :*
HORIZONTAL VENTING NOT SHOWN ON PLAN AND NOT NECESSARY, USE CONVENTIONALY VENTING.