Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T06CM02882
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
09/22/2006 | FRAMING | Approved | IVRS - Inspection :* | |
09/15/2006 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) INSTALL ANTI-SIPHON VALVES ON HOSE BIBS 2) SEPERATE WIRES FROM METAL TRUSS GUSSETS 3) FOUR KING STUDS REQUIRED AT GARAGE OPENING PER SD2 4) EXCESSIVE FOAM AT DRYER VENT BETWEEN DBL 2 X 4 WALL HAS SEPERATED TOP PLATES 5) OUTER SHEATHING OF ROMEX MUST ENTER OUTLET BOX 1/4" MINIMUM AT WATER HTR DECK 6) INSUFFICIENT FIRESTOP AT ENTRY POP OUT 7) FIRESTOP DIVIDER ON EAST WALL 8) FIREBLOCK KITCHEN HOOD VENT 9) PROVIDE LSI REPORT FOR EPOXY INSPECTION |