Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - INTERMEDIATE
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/21/2006 | ELECTRIC - INTERMEDIATE | Approved | IVRS - Inspection :* OK ROUGH |
|
| 07/19/2006 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection :* OK WALLS EXCEPT AT JUNCTION BOX 1. FINISH AS DISCUSSED |
|
| 07/13/2006 | ELECTRIC - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* 1. SUPPORT CEILING WIRES WITHIN 12" OF BOXES ALSO TO BOXES. 2. CANNOT RUN EXPOSED CONDUCTOR IN WALLS OR CEILINGS 3. SUPPORT LOW VOLTAGE CABLES WITHIN 12" OF BOXES AND 6' INTERVALS. 4. WE HAVE CONDUCTOR OVERFILL AT BOXES. INSTALL BOXES SIZE FOR THE NUMBER OF CONDUCTORS & DEVICES 314.16 5. OUTSIDE LIGHT FIXTURE TO USE A BOX. 6. SUPPORT NM CABLE 8' ON HORIZONTAL RUNS. 7. JUNCTION BOXES TO BE ACCESSIBLE ON FINISH 8. OUTLET SPACING PER 210.52 |