Permit: T06CM02869

Parcel: 13104405A


Addresses:

4917 E 29TH ST

Inspection Status: Approved

Inspection History: ELECTRIC - INTERMEDIATE

Date Description Inspector Results Comments
07/20/2006 ELECTRIC - INTERMEDIATE Approved IVRS - Inspection :*
07/18/2006 ELECTRIC - INTERMEDIATE Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. BOXES ARE OVERFILLED
2. SEAL OPEN KO'S
3. GROUNDING SCREWS ARE NOT INSTALLED
4. ROMEX ENTERING METAL BOXES REQUIRES PROPER ROMEX CONNECTORS.
5. J-BOX CANNOT BE CONCEALED BEHIND DRYWALL.
6. ROMEX NEEDS TO BE PROPERLY SECURED WITHIN 8" OR PLASTIC OR BAKELIGHT BOXES.
7. J-BOXES TO BE PROPERLY SECURED.