Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T06CM02869

Parcel: 13104405A


Addresses:

4917 E 29TH ST


Inspection Status: Approved

Inspection History: ELECTRIC - INTERMEDIATE

Permit Number - T06CM02869

Inspection Description - ELECTRIC - INTERMEDIATE

Inspection Status - Approved

Date Description Inspector Results Comments
07/20/2006 ELECTRIC - INTERMEDIATE Approved IVRS - Inspection :*
07/18/2006 ELECTRIC - INTERMEDIATE Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. BOXES ARE OVERFILLED
2. SEAL OPEN KO'S
3. GROUNDING SCREWS ARE NOT INSTALLED
4. ROMEX ENTERING METAL BOXES REQUIRES PROPER ROMEX CONNECTORS.
5. J-BOX CANNOT BE CONCEALED BEHIND DRYWALL.
6. ROMEX NEEDS TO BE PROPERLY SECURED WITHIN 8" OR PLASTIC OR BAKELIGHT BOXES.
7. J-BOXES TO BE PROPERLY SECURED.