Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T06CM02852
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
08/28/2006 | FRAMING | Approved | IVRS - Inspection :* | |
08/25/2006 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) SHEAR INCOMPLETE |
|
08/23/2006 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) PLAN CALLS FOR 5'-5" OF SHEAR AT STAIRWALL 2) REFEE WILL APPLY |
|
08/22/2006 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) NO PAPERWORK |
|
08/21/2006 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) NEED ALL PAPERWORK ON SITE |
|
08/17/2006 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) REVISED SHEAR PLAN NOT COMPLIED WITH |
|
08/16/2006 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) TRAP ARM TO STEEP AT KITCHEN SINK 2) APPROVED TO INSULATE |
|
08/14/2006 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) HOSE BIBS REQUIRE VACUUM BREAKER 2) GROUND METAL BOXES 3) SEAL VAPOR BARRIER 4) FHA STRAPS AND STUD SHOES REQUIRED ON OVERNOTCHED PLATES AND STUDS 5) SECURE BOTH SIDES OF 4 GANG SWITCH BOXES 6) SEAL 2ND FLOOR PENETRATIONS 7) DWV LEAKING 8) STOPPED INSPECTION-HOUSE NOT READY |