Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T06CM02829
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
03/21/2007 | EXT METAL CLIPS/EXT SHEATHING | Approved | ||
11/28/2006 | EXT METAL CLIPS/EXT SHEATHING | Partial Approval | IVRS - Inspection :* NEED RETRO S.E SHEAR WALL, TO BE CHECKED AT INTERMEDIATE. |
|
11/27/2006 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) ITEMS #3, 7 AND 11 NEED RETRO FOR ITME #2 2) NO ACCESS 3) NEED TO INSPECT SHEAR TRANSFER NAILING ON ROOF |
|
11/16/2006 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) SHEAR AT S.W. CORNER GARAGE NOT NAILED ALL THE WAY 2) H.D. NOT NAILED TO SHEAR SOUTH SIDE 3) S.E. CORNER 2ND FLOOR NEEDS DBL STUD AT SHEAR CORNER 4) RSP4 CLIPS BAY WINDOW KING STUD 5) COIL STRAP BAY WINDOW NEEDS MORE NAILING 6) H.D. N.E. CORNER NEEDS TO CATCH ALL SHEAR 7) DBL STUD AT SHEAR CORNER 2ND FLOOR N.W. 8) GLU LAM NEEDS H.25 9) SOFT SPOT 2ND FLOR NEED BLOCKING UNDERNEATH 10) ROOF NAILING EDGE BLOCKING NEEDS NAILS NOT STAPLES 11) SHEAR TRANSFER 2ND FLOOR TO ROOF NOT COMPLETE |