Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - INTERMEDIATE
Permit Number - T06CM02820
Inspection Description - PLUMBING - INTERMEDIATE
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
11/08/2006 | PLUMBING - INTERMEDIATE | Approved | IVRS - Inspection :* | |
10/26/2006 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* - CORRECT SLOPE UNDER FLOOR, SUPPORT TIE IN POINT - USE PROPER TOOLS FOR CAULKING CLOSET FLANGES, SECURE PIPING. - PLAN IS CALLING FOR A 3" DRAIN AT MS. - CORRECT BAND IN CEILING AND CORRECT ALIGNMENT OF OVERHEAD VENT. - OK TO COVER SOUTH WALL W/LAVS AND WC. - OK TO COVER DF'S - RETEST |
|
10/24/2006 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* 1. AIR TEST ON DWV DOWN TO ZERO 2. N/H TO BE INSTALLED IN PRACTICAL ALIGNMENT AND BEN MAY NOT BE CRIMPED OR BUNCHED UP. 3. WATER HEATER PAN DRAIN MAY NOT BE REDUCED. 4. CLOSET FLANGES NOT CAULKED PROPERLY 5. NO EXPANSION TANK 6. BLAKE TEE MAY NOT BE INSTALLED INVERTED ON HORIZ. OVERHEAD PROVIDE APPROVED PLAN AND PERMIT |
|
10/20/2006 | PLUMBING - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999* |