Permit: T06CM02820

Parcel: 10511061R

Inspection Status: Approved

Inspection History: PLUMBING - INTERMEDIATE

Permit Number - T06CM02820

Inspection Description - PLUMBING - INTERMEDIATE

Inspection Status - Approved

Date Description Inspector Results Comments
11/08/2006 PLUMBING - INTERMEDIATE Approved IVRS - Inspection :*
10/26/2006 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
- CORRECT SLOPE UNDER FLOOR, SUPPORT TIE IN POINT
- USE PROPER TOOLS FOR CAULKING CLOSET FLANGES,
SECURE PIPING.
- PLAN IS CALLING FOR A 3" DRAIN AT MS.
- CORRECT BAND IN CEILING AND CORRECT ALIGNMENT OF OVERHEAD VENT.
- OK TO COVER SOUTH WALL W/LAVS AND WC.
- OK TO COVER DF'S
- RETEST
10/24/2006 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
1. AIR TEST ON DWV DOWN TO ZERO
2. N/H TO BE INSTALLED IN PRACTICAL ALIGNMENT AND BEN MAY NOT BE CRIMPED OR BUNCHED UP.
3. WATER HEATER PAN DRAIN MAY NOT BE REDUCED.
4. CLOSET FLANGES NOT CAULKED PROPERLY
5. NO EXPANSION TANK
6. BLAKE TEE MAY NOT BE INSTALLED INVERTED ON HORIZ. OVERHEAD
PROVIDE APPROVED PLAN AND PERMIT
10/20/2006 PLUMBING - INTERMEDIATE Denied IVRS - Inspection :
See detailed listing on site.| 999*