Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - GAS PRESSURE TEST
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/25/2006 | PLUMBING - GAS PRESSURE TEST | Approved | IVRS - Inspection :* TEST OK UTILITY CLEARANCE GIVEN |
|
| 07/12/2006 | PLUMBING - GAS PRESSURE TEST | Denied | IVRS - Inspection : See detailed listing on site.| 999* SYSTEM NOT HOLDING PRESSURE |
|
| 06/23/2006 | PLUMBING - GAS PRESSURE TEST | Denied | IVRS - Inspection : See detailed listing on site.| 999* 200 PSI GAUGE NOT ACCEPTABLE PROVIDE TEST WITH 1/10 PSI INCREMENTATION GAUGE INSTALL WH VENT - USE TYPE B VENT VENT SHALL TERMINATE 1' ABOVE SIDE WALL. INDOOR APPLIANCES LOCATED OUTSIDE ARE REQUIRED TO BE PROTECTED BY AN ENCLOSURE. PROVIDE ELECTRICAL BONDING OF GAS LINE. HAVE AGA VALVES & FLEXES ON SIGHT. INSTALL SEDIMENT TRAP AT WH. |
|
| 05/31/2006 | PLUMBING - GAS PRESSURE TEST | Cancelled | NOT READY FOR GAS INSPECTION |