Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T06CM02807

Parcel: 126042180


Addresses:

822 N COLUMBUS BL

Inspection Status: Approved

Inspection History: ELECTRIC - RECONNECT

Date Description Inspector Results Comments
05/19/2006 ELECTRIC - RECONNECT Approved IVRS - Inspection :*
05/18/2006 ELECTRIC - RECONNECT Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. REMOVE INCORRECT WIRING AT SERVICE, REMOVE ROMEX INSIDE PANEL, REMOVE GFI RECEPTACLE NEXT TO SERVICE, REMOVE UNPROTECTED ROMEX OUTSIDE OF SERVICE, SEAL HOLES ON SIDE AND BOTTOM OF SERVICE.
2. KITCHEN BRACE AT SERVICE TO BE RE-ATTACHED.
3. REMOVE ALL ZIP CORD WIRING INSIDE.
4. LOOSE SWITCH KITCHEN WALL
5. FIXTURE LOOSE KIT CEILING.
6. SWITCH BY KITCHEN DOOR -- GROUNDS IMPROPERLY TIED, SITS IMPROPERLY ON TOP OF RECEPTACLE.
7. SMOKE DETECTORS NEEDED IN SLEEPING AREAS DUE TO OLD AGE OF APT, OLDER WIRING ADDED ON TO THIS APT, WILL NOT RELEASE POWER UNLESS LICENSED ELECTRICAL CONTRACTOR REVIEWS WIRING AT UNIT AND PROVIDES LETTER OF APPROVAL ON WIRING FOR RE-ENERGIZING UNIT.
05/17/2006 ELECTRIC - RECONNECT Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. CALLED AHEAD AT 8:30 FOR 9 AM APPT NO SHOW & LOCKED
2. PRIOR TO RECONNECT "DO NOT ENTER" VIOLATION TO BE CHECKED.