Permit: T06CM02806

Parcel: 126042180


Addresses:

820 N COLUMBUS BL

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
07/12/2006 PLUMBING - FINAL Approved IVRS - Inspection :*
PRESSURE TEST OK
CORRECTIONS MADE OK
OK FOR GAS
UCC LEFT AT METER
06/24/2006 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
CALLED @ 12:55 - "30 to 60 min"
EXTEND PIPING AT WH
PROVIDE A SEDIMENT TRAP AT WH
REPLACE FLUE COLLAR/CONNECTOR
PIPE T&P TO EXTERIOR, TERMINATE 6-24" ABOVE GROUND VERTICALLY.
INSTALL METAL RJ AT FURNACE
RE-PRESSURE TEST
PROVIDE BONDING.