Permit: T06CM02793

Parcel: 141313690

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Permit Number - T06CM02793

Inspection Description - EXT METAL CLIPS/EXT SHEATHING

Inspection Status - Approved

Date Description Inspector Results Comments
09/05/2006 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
08/21/2006 EXT METAL CLIPS/EXT SHEATHING Partial Approval IVRS - Inspection :*
1) MISSING NAILING ON ROOF INCLUDING, SHEAR PANELS
2) NEED DBL HANGER AT SCISSOR TRUSS FRONT
3) REAR SHEARS TILE TO BOTTOM CHORD OF TRUSS
4) TIE BOTTOM CHORD SCISSOR TO WALL WEST
5) (2) SHEAR BLKS REAR BEDROOM #4
6) HANGER AT HIP JACKS GARAGE
7) TWO H.D.'S AT GARAGE SHEAR