Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T06CM02792
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/21/2006 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
| 08/29/2006 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) FINISH THESE ITEMS CIRCLED 2) DON'T LOAD ROOF DRY IN ONLY |
|
| 08/11/2006 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) NAIL OSB TO CONNECT PORCH BEAMS TO COLUMNS 2) MISSING WINDO BRACES AND 1ST-2ND FLOOR BLOCKS 3) MISSING HANGER IN GARAGE GIRDER 4) NAIL OFF HIP HANGER GARAGE 5) H2.5'S AT 4 X 6 GARAGE 6) DEN CEILING, TRUSSES CUT, ( ? HANGERS)-NAILS MISSING 7) NEED HEADER AT GARAGE TO HOUSE MAN DOOR/TO SMALL 8) A.B.'S AND CORRECT NAILS IN ALL P.A.'S, H.D.'S 9) NAILS NEEDED AT FRONT BAY 10) MISSED OSB SHEAR AT KITCHEN SO WALL 11) MISSING HIP HANGER 2ND FLOOR 12) WIND BRACE 2ND FLOOR FRONT WALL 13) FRIEZE BOARDS NOT NAILED TO ROOF 14) REAR WALL 2ND FLOOR, 1ST AND 2ND FLOOR STRAPS NAIL OFF OSB |