Permit: T06CM02772

Parcel: 141095630


Addresses:

6397 E STAR MICA ST


Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T06CM02772

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
12/15/2006 FRAMING Approved IVRS - Inspection :*
12/14/2006 FRAMING Not ready for Inspection IVRS - Inspection :*
1) NOT READY KENNY
12/13/2006 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) NO GAS TEST
2) KITCHEN SINK REQUIRES VENT TO ROOF
3) STAIR WINDER MUST BE 6" ON NARROW END
4) HALL TUB NOT PROPERLY VENTED
5) FIRESTOP W/H VENT
6) FIRESTOP REQUIRES 2 LAYERS 1/2" OSB FRONT BEDROOM
7) NO DWV TEST
8) AIR INTAKE MUST BE 10 FT FROM SEWER VENT