Permit: T06CM02746


Addresses:

2616 N COLUMBUS BL


Inspection Status: Approved

Inspection History: PLUMBING - GAS RECONNECT

Permit Number - T06CM02746

Inspection Description - PLUMBING - GAS RECONNECT

Inspection Status - Approved

Date Description Inspector Results Comments
05/23/2006 PLUMBING - GAS RECONNECT Approved IVRS - Inspection :*
03050 -- APPROVED GAS CARD AT METER
03090 -- APPROVED
05/18/2006 PLUMBING - GAS RECONNECT Partial Approval IVRS - Inspection :*
10 PSI TEST FROM METER EXISTING PIPING TO WATER HEATER/FURNACE ONLY.
1. WATER HEATER T&P DRAIN SHALL GRAVITY DRAIN TO DAYLIGHT OR PROVIDE CITY SIGNED PETITION OF APPEAL FOR ALTERNATE FORM OF TEMPERATURE & PRESSURE RELIEF ONSITE WITH CORRECT INSTALLATION.
2. VENTS FROM WATER HEATER & FURNACE TO HAVE 3-GALV SCREWS AT EACH JOINT AND BE MADE UP CORRECTLY.
3. VENTS FROM WATER HEATER & FURNACE TO BE 3' ABOVE TOP OF COOLER INTAKE WHEN WITHIN 10' OF INTAKES WITH APPROVED DOUBLE WALL VENT PIPING & APPROVED VENT CAPS.
05/15/2006 PLUMBING - GAS RECONNECT Not ready for Inspection IVRS - Inspection :*