Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T06CM02707

Parcel: 140553700

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
10/19/2006 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
09/07/2006 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. 112.5 REQ'D ON VIGA @ FRONT PORCH
2. A35 REQ'D @ LEDGER BACK PORCH