Inspection History Details
Inspection Status: Approved
Inspection History: BUILDING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 03/15/2007 | BUILDING - FINAL | Approved | IVRS - Inspection :* | |
| 02/27/2007 | BUILDING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. PAINT ABS VENTS ON ROOF 2. INSTALL BREAKER FOR DRYER CIRCUIT 3. SEAL STUCCO AROUND TPR LINE BY AC 4. MIN. 6" FALL REQ'D ON EXTERIOR GRADE AWAY FROM HOUSE 5. SET SCREW MISSING ON VACUUM BREAKER BY AC 6. SEAL WALL ABOVE DECK BEHIND WATER HTR 7. BOND JUMPER REQ'D ON SUPPLY DUCT IN GARAGE 8. MARK HEAT STRIP LABEL ON FURN 9. SEAL GARAGE CEILING @ LINESET 10. INSTALL DISHWASHER DRAIN ATTACHED TO UNDERSIDE OF COUNTERTOP 11. ANTI-TIP REQ'D ON RANGE 12. STOPPED INSPECTION |