Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T06CM02703
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/01/2006 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
| 11/30/2006 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) SHIM 3 POINT BEARING TRUSSES AND CLIP TO WALL 2) RAT RUN REQUIRED ON TRUSS B01 PER SPECS 3) BLOCK ROOF SHEATHING PANELS LESS THAN 24" IN WIDTH 4) ROOF NAILING OVER PENETRATED |
|
| 11/20/2006 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) GABLE END BRACING REQUIRED PER DETAIL 1/S4 2) A35'S REQUIRED ON GABLE ENDS MINIMUM 32" ON CENTER PER DETAIL 1/S4 3) TIE GABLE RAFTER TO COLUMN AT ENTRY 4) COMPLETE HOLDOWN INSTALLATION 5) NAILS IN STRUCTURAL PANELS OVER PENETRATING SHEATHING 6) MAINTAIN 6" NAIL PATTERN ON EDGE SUPPORT STRUCTURAL PANELS 7) COMPLETE ANCHOR BOLTS 8) PROVIDE CITY APPROVED TRUSS SPECS 9) STRAP OUTSIDE CORNERS OF NORTH WALL-MISSING CABIN TIES 10) 2' MIN OVERLAP REQUIRED ON DBL TOP PLATES-EAST WALL 11) PROVIDE ENGINEER REPAIR FOR BROKEN TRUSS 12) RELIEVE INTERIOR TOP POALTES AT 2 POINT BEARING TRUSSES 13) PROVIDE LADDER 14) STOPPED INSPECTION-HOUSE NOT READY |