Permit: T06CM02700

Parcel: 12702231F


Addresses:

5102 E SPEEDWAY BL

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
08/01/2007 PLUMBING - FINAL Approved IVRS - Inspection :*
06/26/2007 PLUMBING - FINAL Denied BACKFLOW CERTS OK
VAC BREAKERS INSTALLED
CORRECT LEAKS AT HS AND AT ICEE
04/19/2007 PLUMBING - FINAL Partial Approval IVRS - Inspection :*
RECEIVED 13 BACKFLOW CERTS
NEED 1 ADDITIONAL BACKFLOW CERT FOR NEW ASSEMBLY SERVICE ICE MACHINE
CONNECT & IDENTIFY ASSEMBLY
HB VAC BREAKER
02/27/2007 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1. ICEE WATER SUPPLY HAS AN UNKNOWN WATER CONNECTION.
2. DN STRM OF RP IDENTIFY AND SEPARATE
3. ADDITIONAL BACKFLOW PROTECTION MAY BE NEEDED
4. PROVIDE BACKFLOW CERTS
5. CORRECT LEAK ON HS TAILPIECE
6. INSTALL HB VAC BREAKER AT EXTERIOR HB
10/03/2006 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
DRAINS FROM FROSTER MACHINES SHALL GRAVITY DRAIN WITHOUT KINKS & OBSTRUCTION IN TUBING.