Permit: T06CM02695

Parcel: 12708187F


Addresses:

5405 E BROADWAY BL


Inspection Status: Approved

Inspection History: PLUMBING - ROUGH, SOIL

Permit Number - T06CM02695

Inspection Description - PLUMBING - ROUGH, SOIL

Inspection Status - Approved

Date Description Inspector Results Comments
07/06/2006 PLUMBING - ROUGH, SOIL Approved IVRS - Inspection :*
06/22/2006 PLUMBING - ROUGH, SOIL Partial Approval IVRS - Inspection :*
- INSTALLED PER REDLINE CHANGES ON APPROVED PLANS.
- INSTALL CLEANOUTS ON LAUNDRY AND MOP SINK.
- INSTALL BACKING AT M.S.
- OK TO COVER IF REVISED PLAN REFLECTS REDLINE CHANGES.
- PROVIDE TEST ON TUB WASTE & OVERFLOW AT TIME OF INSTALLATION.
06/21/2006 PLUMBING - ROUGH, SOIL Not ready for Inspection IVRS - Inspection :*
06/19/2006 PLUMBING - ROUGH, SOIL Denied IVRS - Inspection :
See detailed listing on site.| 999*
- VERTICAL TO HORIZONTAL CHANGE OF DIRECTIONS SHALL BE MADE W/WYE PATTERN FITTINGS -- INSTALL SWEEP AT UPPER TERMINAL.
- NOT INSTALLED PER PLAN - PROVIDE REVISION OR REDLINES FOR PARTIAL APPROVAL.
- CALL FOR INTERMEDIATE INSP. ALSO, NEED SAFETY PLATES, PIPE SUPPORTS.