Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T06CM02664
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
11/13/2006 | FRAMING | Approved | IVRS - Inspection :* | |
11/03/2006 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) RED HEADS/ANCHOR BOLTS LOOSE THROUGHOUT 2) CANNOT LOCATE DETAIL FOR ITEM 1 10/30/06 |
|
10/30/2006 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) CHECK PLANS STRAPS MISSING BETWEEN SHEARWALLS AT STAIRS 2) LOOS NUTS THROUGHOUT |
|
10/23/2006 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) MISSING A STUD UPSTAIRS LAUNDRY ROOM 2) BROKEN STUD MASTER BOLT 3) FIREBLOCK CHASE UPSTAIRS 4) FIREBLOCK KITCHEN 5) WINDOW NEEDS BUTTERFLY RE-INFORCEMENT 6) WINDOW KITCHEN NOT COMPLETE 7) A/C CABLE NEED TO BE CAULKED 8) NO WATER DWV TEST 9) DUCT MASTER NOT CONNECTED 10) ADD STUD TO GARAGE |