Inspection History Details
Inspection Status: Partial Approval
Inspection History: FRAMING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/21/2006 | FRAMING | Partial Approval | IVRS - Inspection :* | |
| 09/21/2006 | FRAMING | Approved | IVRS - Inspection :* | |
| 09/19/2006 | FRAMING | Partial Approval | IVRS - Inspection :* 1) TIGHTEN RED HEADS 2) HTT 16 TO BE NAILED WITH 16D COMMONS 0.162 X 3 1/4 (AT FRONT OF GARAGE) 3) COMPLETE WINDOWS 4) REPAIR PAPER MASTER BEDROOM AND BATH 5) MAKE UP SWITCH BOX BEDROOM 2 AND FEED RECEPTACLE 6) NAIL STOP ELECTRIC BREAKFAST NOOK AND WATER 7) NAIL OFF FHA STRAPS TOP PLATE WATER SUPPLY WITH 16D NAILS 8) LEAK IN OVERFLOW OF TUB HALL BATH 9) GLUE 90 DEGREE ON MASTER SHOWER VENT 10) CHECK FOR FILTER ON MAKE UP AIR JUMPER BOX L/R AT FINAL |