Permit: T06CM02628

Parcel: 141311370

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Permit Number - T06CM02628

Inspection Description - EXT METAL CLIPS/EXT SHEATHING

Inspection Status - Approved

Date Description Inspector Results Comments
08/25/2006 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
08/22/2006 EXT METAL CLIPS/EXT SHEATHING Partial Approval IVRS - Inspection :*
1) SHEAR PANEL'S MISSING AT GARAGE
2) NAIL PANEL TO ROOF AT REAR
07/12/2006 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) MISSED NAILING ON ROOF
2) MISSING RAT RUNS
3) NAIL BLK PANELS TO ROOF USE 10D'S SO THEY CAN BE SEEN FROM BELOW
4) MISSED TWO
5) RAT RUNS ON A-1 TRUSSES
6) DBL H2.5 ON ALL GIRDERS
7) USE 16D IN ALL P.A.'S-SEE PLANS