Inspection History Details
Inspection Status: Approved
Inspection History: ROOF NAILING
Permit Number - T06CM02627
Inspection Description - ROOF NAILING
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/24/2006 | ROOF NAILING | Approved | IVRS - Inspection :* | |
| 08/14/2006 | ROOF NAILING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. FOUR 3PT TRUSSES TURNED OR IN WRONG LAYOUT 2. CUT NOTCH IN T/PLATE WHERE 2PT TRUSSES ARE BEARING AT INTERIOR, DON'T SHIM 3. REAR SHEAR TRANSFER NOT DONE 4. MISSING SHEAR PANELS BETWEEN TRUSSES NAIL TO ROOF (LAYOUT) IS EVERY OTHER BAY 5. MISSING RAT RUNS 14/DTI |
|
| 08/09/2006 | ROOF NAILING | Not ready for Inspection | IVRS - Inspection :* |