Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - INTERMEDIATE
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 03/30/2007 | PLUMBING - INTERMEDIATE | Approved | ||
| 02/27/2007 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* 1. REVISED PLANS DO NOT HAVE CITY APPROVAL 2. PERM CAPS BELOW FLOOR OK TO COVER 3. VENT CAPPED IN CEILING AND SUPPORTED 4. CAP ON ROOF ALSO, PROTECT ALL PLASTIC FROM UV RAYS FOR FINAL |
|
| 02/14/2007 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* DAVID 609-8066 CLOSET FLANGES OK DO PLANS SPEC LAV CARRIERS? |
|
| 02/13/2007 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* SECURE RING E0 AS NOT TO MOVE TRY A DIFFERENT CORROSION RESISTANT FASTENER |
|
| 01/02/2007 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* NEED PLAN REVISION FOR DELETION OF 2ND TOILET RM AND REDUCTION OF 1 1/4 PIPE SIZING |
|
| 12/13/2006 | PLUMBING - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999* WATER PIPING NOT PER PLAN |
|
| 10/25/2006 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* - NEED PLANS & PERMIT FOR INSPECTION - TEST ON ABS DWV AT BACK TO BACK BATHROOMS OK - OK TO INSULATE HW IF INSTALLED PER PLAN. - CLOSET FLANGES NOT SECURE. - FLANGES ARE TO BE INSTALLED PER UPC - INSTALLATION STANDARDS FOR ABS. 155 REQUIRES TOP OF FLANGE TO BE 1/4" ABOVE FF, BUT SHALL ALSO REST ON A FIRM BASE. FLANGES ARE ALSO REQUIRED TO BE FASTENED TO FLOOR W/CORROSION RESISTANT FASTENERS. |