Permit: T06CM02615

Parcel: 13325186E


Addresses:

8474 E SPEEDWAY BL

Inspection Status: Approved

Inspection History: PLUMBING - INTERMEDIATE

Date Description Inspector Results Comments
03/30/2007 PLUMBING - INTERMEDIATE Approved
02/27/2007 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
1. REVISED PLANS DO NOT HAVE CITY APPROVAL
2. PERM CAPS BELOW FLOOR OK TO COVER
3. VENT CAPPED IN CEILING AND SUPPORTED
4. CAP ON ROOF ALSO, PROTECT ALL PLASTIC FROM UV RAYS FOR FINAL
02/14/2007 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
DAVID 609-8066

CLOSET FLANGES OK
DO PLANS SPEC LAV CARRIERS?
02/13/2007 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
SECURE RING E0 AS NOT TO MOVE
TRY A DIFFERENT CORROSION RESISTANT FASTENER
01/02/2007 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
NEED PLAN REVISION FOR DELETION OF 2ND TOILET RM
AND REDUCTION OF 1 1/4 PIPE SIZING
12/13/2006 PLUMBING - INTERMEDIATE Denied IVRS - Inspection :
See detailed listing on site.| 999*
WATER PIPING NOT PER PLAN
10/25/2006 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
- NEED PLANS & PERMIT FOR INSPECTION
- TEST ON ABS DWV AT BACK TO BACK BATHROOMS OK
- OK TO INSULATE HW IF INSTALLED PER PLAN.
- CLOSET FLANGES NOT SECURE.
- FLANGES ARE TO BE INSTALLED PER UPC
- INSTALLATION STANDARDS FOR ABS.
155 REQUIRES TOP OF FLANGE TO BE 1/4" ABOVE FF, BUT SHALL ALSO REST ON A FIRM BASE. FLANGES ARE ALSO REQUIRED TO BE FASTENED TO FLOOR W/CORROSION RESISTANT FASTENERS.