Inspection Status: Approved
Inspection History: PLUMBING - INTERMEDIATE
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 02/13/2007 | PLUMBING - INTERMEDIATE | Approved | IVRS - Inspection :* TRY A DIFFERENT TYPE OF CONCRETE ANCHOR ? LAV CARRIES - PROVIDE PLAN |
|
| 12/13/2006 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* WALLS AND CEILING OK TO COVER |
|
| 12/06/2006 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* 1. TESTS OK 2. SECURE ABS MID-STORY 3. INSULATE HW PIPING, USE ADHESIVE AT JOINTS 4. SUPPORT OVERHEAD COPPER AT 6' INTERVALS 5. CLOSET FLANGES SHALL BE SECURED TO FLOOR W/FASTENERS. 6. TOP OF FLANGE SHALL BE 1/4" ABOVE FF AND SHALL REST ON A FIRM BASE PER UPC I5 5 THIS CAN BE INSPECTED AFTER FLOORING. |