Permit: T06CM02573

Parcel: 108203200


Addresses:

4162 N FORTUNE LP

Inspection Status: Approved

Inspection History: PLUMBING - INTERMEDIATE

Date Description Inspector Results Comments
11/08/2006 PLUMBING - INTERMEDIATE Approved IVRS - Inspection :*
1. PVC DWV THRU ROOF OK
2. CORRECTIONS MADE OK
3. OK TO COVER ALL AREAS
10/20/2006 PLUMBING - INTERMEDIATE Denied IVRS - Inspection :
See detailed listing on site.| 999*
- REPLACE SUN BURNED PVC AT 3" RISER TO 2ND FL
- WATER PUDDLED UNDER TUB, CHECK FOR LEAK
- PLAN CALLS FOR VTR AT KIT SINK, INSTALL PER PLAN OR REVISE
- PROVIDE LISTING FOR 2ND LEVEL CLOSET FLANGE ALSO, FLANGES SHALL BE INSTALLED PER 2003 169 WHICH REQUIRES TOP OF FLANGE TO BE 1/4" ABOVE FF AND TO BE SECURELY FASTENED TO FLOOR.

INSTALL HB VAC BREAKERS OR REMOVE HBS