Inspection Status: Approved
Inspection History: PLUMBING - INTERMEDIATE
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/08/2006 | PLUMBING - INTERMEDIATE | Approved | IVRS - Inspection :* 1. PVC DWV THRU ROOF OK 2. CORRECTIONS MADE OK 3. OK TO COVER ALL AREAS |
|
| 10/20/2006 | PLUMBING - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999* - REPLACE SUN BURNED PVC AT 3" RISER TO 2ND FL - WATER PUDDLED UNDER TUB, CHECK FOR LEAK - PLAN CALLS FOR VTR AT KIT SINK, INSTALL PER PLAN OR REVISE - PROVIDE LISTING FOR 2ND LEVEL CLOSET FLANGE ALSO, FLANGES SHALL BE INSTALLED PER 2003 169 WHICH REQUIRES TOP OF FLANGE TO BE 1/4" ABOVE FF AND TO BE SECURELY FASTENED TO FLOOR. INSTALL HB VAC BREAKERS OR REMOVE HBS |