Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/04/2007 | PLUMBING - FINAL | Approved | IVRS - Inspection : FUTURE WATER LINES INSTALLED PER PLAN, WITH REDLINE CHANGES FOR 2" SCH 40 PVC. OK TO COVER. |
|
| 10/02/2007 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* - TEST NOT READY - INSTALL PIPING ON A FIRM BED FOR ITS ENTIRE LENGTH - REMOVE CONCRETE CHUNKS THAT ARE NEAR OR MAY FALL ON PIPING - PIPING NOT 12" DEEP NEAR DRIVE - ALSO, REDLINE PLANS FOR CHANGE OF SIZE AND MATERIAL TYPE - HAVE PLANS ON SITE FOR INSP. |
|
| 10/01/2007 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* REDLINE CHANGE OF SIZE TRACER WIRE SHADE TEST |