Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T06CM02494
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/22/2006 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
| 09/21/2006 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) OUTRIGGERS MISSING 2) BRACING NOT PER PLAN 3) NAIL FRIEZE BOARDS PER DETAIL 7-8 4) INCOMPLETE-STOPPED INSPECTION |
|
| 09/19/2006 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) PROVIDE TRUSS BRACE AS PER APPROVED DRAWINGS 2) SCREW SHEARWALLS AS PER SCHEDULE 3) NAIL FRIEZE BOARDS PER DETAIL 7-8 4) BRACE GABLE ENDS PER DETAIL 10-8 5) NAIL ALL HOLDOWNS |
|
| 09/05/2006 | EXT METAL CLIPS/EXT SHEATHING | Cancelled | ||
| 09/05/2006 | EXT METAL CLIPS/EXT SHEATHING | Not ready for Inspection | IVRS - Inspection :* |