Inspection History Details
Inspection Status: Approved
Inspection History: BUILDING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/02/2007 | BUILDING - FINAL | Approved | IVRS - Inspection :* | |
| 06/29/2007 | BUILDING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) PATCH STUCCO-WERE BROKEN AT REAR OF HOUSE 2 PLACES 2) PAINT VTR ON ROOF 3) CUT BACK LINKS FROM MESQUITE TREE-FOR CLEARANCE AT WEATHER HEAD 4) NEED TO PROTECT MAIN WATER SUPPLY AT RISER 5) MISSING SMOKIE IN HALLWAY 6) A/C UNIT NEEDS TO BE TRAPPED 7) EXTEND WALKWAY TO OPENING AT ATTIC |