Permit: T06CM02483

Parcel: 115155220


Addresses:

819 W CALLE RETAMA

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
09/26/2006 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
09/20/2006 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) SET NAILS, STAPLES FLUSH WITH SHEATHING
2) BLOCK SHEATHING BETWEEN TRUSSES AND NAIL THROUGH SHEATHING INTO BLOCKING AT WEAK-SPONGY AREAS MOSTLY MARKED IN PAINT
3) REPLACE-EXCESSIVELY SPAULLED HOLDOWNS BOTH SIDES GARAGE (2 EACH SIDE) WITH EPOXIED HOLDOWNS
4) INSTALL PLATE BOLTS WITHIN 12" EACH END, EACH BOTTOM PLATE WIND BRACE PANEL