Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T06CM02476

Parcel: 129091600


Addresses:

1634 E 28TH ST

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
04/06/2007 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
04/03/2007 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
COMPLY WITH DETAIL 4-6
DBL STUDS REQUIRED AT HOLDDOWNS
03/28/2007 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) NEED RETRO FOR HOLDOWNS IN GARAGE AND S.E. CORNER OF HOUSE
2) NO CONNECTION TO EDGE BLOCKING
3) REAR OF ROOF NEED TO ADD BLOCKING WHERE PLYWOOD WRONG DIRECTION
4) MISSING CLIPS ON HEADERS
03/20/2007 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) STRAP GABLE END TRUSSES TO TOP PLATES 48" ON CENTER
2) BRACE PANELS SHALL BE NAILED TO TOP PLATES
3) REMOVE SLACK FROM HOLDOWNS
4) ALTERNATE HOLDOWNS REQUIRED AT WEST GARAGE JAMB
5) NEED APPROVED DETAILS FOR ALL FRAMING
03/19/2007 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) NO PLANS ON SITE
2) NO ROOF ACCESS