Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
08/22/2006 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
08/18/2006 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
Work is not complete enough to inspect.| 950*
1) NO CHANGE FROM 8/17/06 INSPECTION. NEXT FAILURE WILL BE CHARGED A REINSPECTION FEE. NO INSPECTION BEYOND FRONT OF HOUSE
08/17/2006 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
Work is not complete enough to inspect.| 950*
1) SECOND FLOOR #6 SHEARWALL TO SHORT-SEE PLAN
2) CS 18 STRAPS MISSING THROUGHOUT
3) SHEARWALLS NOT NAILED
4) NOT OF SHEAR SCHEDULE NOT COMPLIED WITH
5) STOPPED INSPECTION-HOUSE NOT READY-TOO MANY ITEMS