Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/25/2006 | FRAMING | Approved | IVRS - Inspection :* | |
| 07/24/2006 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) GARAGE SHEARWALL 2 TOP PLATE REQUIRES CLIP 2) GARAGE FRONT SHEARWALL ONE STUD NOT NAILED |
|
| 07/21/2006 | FRAMING | Not ready for Inspection | IVRS - Inspection :* 1) NOT READY PER SUPER J.J. |
|
| 07/20/2006 | FRAMING | Denied | IVRS - Inspection : Work is not complete enough to inspect.| 950* 1) GARAGE SHEAR WALL 2 MUST BE CONNECTED TO FLOOR TRUSS SYSTEM-SEE 6/SD3 2) KINKED WIRES BY HOME RUNS 3) NAIL PROTECT WIRES WITHIN 1 1/4" OF STUD SURFACE 4) YOU HAVE REQUESTED A GAS INSPECTION BUT HAVE NOT INSTALLED GAS LINE. EITHER INSTALL GAS LINE OR HAVE IT REMOVED FROM YOUR PERMIT 5) STAIR WELL LIGHT MUST BE 6'-8" ABOVE STAIR PLANE 6) MAX ALLOWED STAIR-RISE DIFFERENCE 3/8" EXCEEDED 7) INTERIOR WALLS MISSING DTC CLIPS PER 5/5D4 8) NO ADDRESS ON ELECTRIC PANEL 9) STOPPED INSPECTION-TOO MANY ITEMS |
|
| 07/19/2006 | FRAMING | Denied | IVRS - Inspection : Work is not complete enough to inspect.| 950* 1) STUCCO LATHE MUST BE COMPLETE BEFORE INTERMEDIATE INSPECTIONS CAN BE MADE 2) YOU MUST EITHER REMOVE GAS 03050 FROM YOUR INSPECTION CARD THRU CITY OF TUCSON OR INSTALL GAS LINES |