Permit: T06CM02466

Parcel: 140550780

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
07/25/2006 FRAMING Approved IVRS - Inspection :*
07/24/2006 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) GARAGE SHEARWALL 2 TOP PLATE REQUIRES CLIP
2) GARAGE FRONT SHEARWALL ONE STUD NOT NAILED
07/21/2006 FRAMING Not ready for Inspection IVRS - Inspection :*
1) NOT READY PER SUPER J.J.
07/20/2006 FRAMING Denied IVRS - Inspection :
Work is not complete enough to inspect.| 950*
1) GARAGE SHEAR WALL 2 MUST BE CONNECTED TO FLOOR TRUSS SYSTEM-SEE 6/SD3
2) KINKED WIRES BY HOME RUNS
3) NAIL PROTECT WIRES WITHIN 1 1/4" OF STUD SURFACE
4) YOU HAVE REQUESTED A GAS INSPECTION BUT HAVE NOT INSTALLED GAS LINE. EITHER INSTALL GAS LINE OR HAVE IT REMOVED FROM YOUR PERMIT
5) STAIR WELL LIGHT MUST BE 6'-8" ABOVE STAIR PLANE
6) MAX ALLOWED STAIR-RISE DIFFERENCE 3/8" EXCEEDED
7) INTERIOR WALLS MISSING DTC CLIPS PER 5/5D4
8) NO ADDRESS ON ELECTRIC PANEL
9) STOPPED INSPECTION-TOO MANY ITEMS
07/19/2006 FRAMING Denied IVRS - Inspection :
Work is not complete enough to inspect.| 950*
1) STUCCO LATHE MUST BE COMPLETE BEFORE INTERMEDIATE INSPECTIONS CAN BE MADE
2) YOU MUST EITHER REMOVE GAS 03050 FROM YOUR INSPECTION CARD THRU CITY OF TUCSON OR INSTALL GAS LINES