Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T06CM02465
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
12/04/2006 | FRAMING | Approved | IVRS - Inspection :* | |
11/30/2006 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) INSTALL VACUUM BREAKERS ON HOSE BIBS 2) INSTALL ANCHOR BOLTS ON EITHER SIDE OF SPLIT PLATE IN GARAGE 3) SEAL VAPOR BARRIER 4) INSULATE BEHIND SHOWER 5) BANG PLATE OVER 1/2" ABS IN LINEN 6) ECCESSIVE SLOPE ON 1 1/2" TRAP ARM IN HALL BATH 7) BLOWN FIREBLOCK IN L.R. 8) ROOF VENT MISSING OVER MASTER BATH 9) STOPPED INSPECTION |