Permit: T06CM02412

Parcel: 13323190A


Addresses:

7812 E SPEEDWAY BL


Inspection Status: Not ready for Inspection

Inspection History: PLUMBING - FINAL

Permit Number - T06CM02412

Inspection Description - PLUMBING - FINAL

Inspection Status - Not ready for Inspection

Date Description Inspector Results Comments
07/01/2008 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
CONTRACTOR TO RESCHEDULE
06/19/2008 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
05/28/2008 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
-- NO COPPER TUBING ALLOWED DOWN STREAM OF RP
AT CARBONATOR.
-- PROVIDE PROPER INSTALLATION OF WATER AND DRAIN PIPING TO EXTERIOR RO MACHINE, REMOVE OR PERMIT SEPARATELY
09/07/2007 PLUMBING - FINAL Partial Approval IVRS - Inspection :*
IRR CERTS RECEIVED
CORRECTLY INSTALL INDIRECT PIPING AT BEV. DISP.
08/30/2007 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
08/22/2007 PLUMBING - FINAL Partial Approval IVRS - Inspection :*
- SEAFOOD 3 COMP SINK HAS LEAK AT P-TRAP
- SODA DRAINS LEAKING PRIME & GLUE PVC AND
SUPPORT PIPING
- CONNECT ICE & ICE TEA DISPENSERS TO BACKFLOW ASSEMBLIES
BACKFLOW CERTS RECEIVED EXCEPT FOR IRR ASSEMBLY ON EAST SIDE.
08/02/2007 PLUMBING - FINAL Partial Approval - FLORAL SINK OK
- MEAT DEPT. SEE PREVIOUSLY LISTED CORRECTION
AT BEV. DISP. ICE TEA BREWER REQUIRES BACKFLOW PROTECTION.
- RO WATER MACHINES REQUIRE BACKFLOW PROTECTION
- IRRIGATION ASSEMBLY LEAKING, REPAIR & CERTIFY
- CAP C1 PIPE AT RO
- AT BEV. DISP. PROPERLY ASSEMBLE, SLOPE AND SUPPORT INDIRECT WASTE PIPING ON SODA AND ICE TEA.
- ALL CLEANOUTS INSIDE AND OUT SHALL BE SEALED.
- EXTEND INTERCEPTOR VENT TO ABV PARAPET
- PROVIDE APPROVED PLAN REVISIONS FOR ALL CHANGES
- LIST MAY NOT BE COMPLETE
REDLINE DRAWINGS NOT ON SITE
PLUMBER NOT ON SITE
06/05/2007 PLUMBING - FINAL Partial Approval IVRS - Inspection :*
RECEIVED BACKFLOW CERTS FOR STARBUCKS
05/24/2007 PLUMBING - FINAL Partial Approval IVRS - Inspection :*
STARBUCKS PROVIDE BACKFLOW CERTS
05/21/2007 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
STARBUCKS
1. PROVIDE DIRECT DRAIN FOR HAND SINK.
2. REPAIR LEAKS UNDER SINKS
3. REPAIR DRAIN PIPE FOR INDIRECT DRAIN FOR 3-COMP SINK

BAKERY
1. REPAIR LEAK ON WATER PIPING OVERHEAD GOING
TO 3-COMP SINK
OK TO COVER WALL IN BAKERY FOR 3-COMP SINK
05/10/2007 PLUMBING - FINAL Partial Approval IVRS - Inspection :*
PHARMACY TOILET RMS AND SINK OK
04/03/2007 PLUMBING - FINAL Partial Approval IVRS - Inspection :*
WATER LINE AT RP RELOCATION IS OK TO COVER.
REPLACE MISSING TEST COCK
PROVIDE BACKFLOW CERTIFICATION
MOP SINK & WH FINAL OK
ABV CEILING WH AT PHARMACY TR OK
03/21/2007 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1. WATER SUPPLY PROTECT YARD WATER BEFORE COVERING AND THRU WALL BEFORE CALLING FOR INSPECTION.
2. INSTALL HCS PER DETAIL NO. 401
3. WATER PIPE TO FLORAL OK
01/18/2007 PLUMBING - FINAL Partial Approval IVRS - Inspection :*
1. PRODUCE AREA, WH AND SINKS OK
2. DISP NOT YET INSTALLED
3. USE FACTORY TAPPED CLEAN OUT PLUGS TO RECEIVE SCREW FROM COVER.
4. USE ADHESIVE TO SEAL JOINTS ON INSULATION.