Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T06CM02374
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
04/10/2007 | FRAMING | Approved | IVRS - Inspection :* | |
04/09/2007 | FRAMING | Not ready for Inspection | IVRS - Inspection :* 1) NOT READY PER SUPER |
|
04/04/2007 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. PROVIDE DOCUMENTATION FOR CUT SLAB @ M. BATH 2. PROVIDE MIN. 2" CLEARANCE BELOW WEEP SCREED @ FRONT PORCH 3. 1" MIN. CLEARANCE REQUIRED FROM WATER HTR B-VENT TO ROOFING MATERIALS. 4. PROVIDE MIN. 10' CLEARANCE FROM PLUMBING VENT TO FRESH AIR INTAKE. 5. REPAIR BLOWN FIREBLOCK IN M. CLOSET 6. REPAIR OVERNOTCHED TOP PLATE & STUDS IN M.BATH 7. SHIM HDRS WHERE NEEDED 8. INCOMPLETE PLAN -- NO MECH. PAGE 9. STOPPED INSPECTION |