Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T06CM02356
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
01/04/2007 | FRAMING | Approved | IVRS - Inspection :* | |
12/28/2006 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) ADD BLOCK BEHIND STAIR HANGER 2) CHANGE HANGER ON MG08 TRUSS TO HUS HANGER 3) OK TO INSULATE |
|
12/19/2006 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* |
|
12/14/2006 | FRAMING | Cancelled | IVRS - RI canceled | |
11/29/2006 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) FIRE BLOCK DUCT CHASES 2) NORTH FLOORING AT TOP OF STAIRS WEAK 3) NAIL OFF H/D N.W. CORNER 4) TIGHTEN ALL RED HEADS 5) REPLACE STUD AT BEARING WALL BY DOOR OF POWDER ROOM 6) REPAIR AT GAS PIPE 7) COMPLETE AT FRONT DOOR 8) BOND GAS PIPE 9) REROUTE WIRE IN DINING AREA TO RECEPTACLE 10) SECONDARY A/C DRAIN NEEDS TO GO TO OBVIOUS LOCATION 11) SLOPE ON WATER HEATER B-VENT MUST BE AT LEAST 30 DEGREE FROM HORIZONTAL 12) REPAIR DUCT BOOT S.E. BEDROOM |
|
11/20/2006 | FRAMING | Not ready for Inspection | IVRS - Inspection :* 1) NO WATER |