Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T06CM02352
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/22/2006 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
| 06/19/2006 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) INSTALL ALL LATERAL BRACING A1A, A1AG & A22 2) TRUSS A1CG WHAT IS A STITCH PLATE, A12 WHAT IS ?8 MARKED ON WEB ? A17 W8 W10 ? ON WEB MEMBER 3) WRONG NAILS IN AHUS 26 HANGERS USE 16D'S WIND BRACING AT EACH CORNER AND AT 25 ON CENTER/DRAG STRUT NAILING TO ROOF 6" ON CENTER |