Permit: T06CM02336

Parcel: 124130570


Addresses:

1116 E 14TH ST #02

Inspection Status: Approved

Inspection History: ELECTRIC - FINAL

Date Description Inspector Results Comments
08/23/2006 ELECTRIC - FINAL Approved IVRS - Inspection :*
08/22/2006 ELECTRIC - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) ARC FAULT PROTECTION REQUIRED IN SLEEPING ARE
2) BUBBLED COVER REQUIRED ON EXT. OUTLET
08/21/2006 ELECTRIC - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
07/31/2006 ELECTRIC - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. GFI OUTLETS NOT WORKING PROPERLY
2. SERVICE PANEL/SUB-PANEL MUST BE WEATHERPROOF
3. NEUTRAL & GROUND CAN'T SHARE BUS IN SUB-PANEL
4. ELECTRICAL NOT COMPLETE @ SERVICE PANEL.
5. FILL OPEN KNOCKOUT IN RECEPTACLE HOUSING ON ROOF
6. STOPPED INSPECTION.