Permit: T06CM02334

Parcel: 11107313A

Inspection Status: Approved

Inspection History: PLUMBING - ROUGH, SOIL

Permit Number - T06CM02334

Inspection Description - PLUMBING - ROUGH, SOIL

Inspection Status - Approved

Date Description Inspector Results Comments
10/17/2006 PLUMBING - ROUGH, SOIL Approved IVRS - Inspection :*
INSTALL 4" CLEANOUT AT W.C RM 115
CALL FOR PLUMBING PRE-SLAB INSP. PRIOR TO CONCRETE.
10/13/2006 PLUMBING - ROUGH, SOIL Partial Approval IVRS - Inspection :*
SWEEP OK
2 1/2" K COPPER W/BRAZED 90 AND 100 PSI TEST
PROTECT COPPER FROM CONCRETE -
INSTALL BRANCH FOR 3" P-7 114
NO PIPING SHALL BE DIRECTLY EMBEDDED IN CONCRETE
OK THRU COL. F TOILET RM.
SOUTH OF F CORRECT SLOPE
09/28/2006 PLUMBING - ROUGH, SOIL Partial Approval IVRS - Inspection :*
- POST ADDRESS
- SWEEP REQUIRED AT VERTICAL TO HORIZONTAL CHANGES OF DIRECTION.
- SEC. D OUT THROUGH TWO WAY CO, MAIN LINE ONLY W/RISERS CAPPED OFF, OK TO COVER EXCEPT FOR UPPER TERMINAL CLEANOUT SHALL BE A WYE PATTERN FITTING OR SWEEP OF EQUIVALENT RADIUS.