Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: REINFORCED MASONRY PRE-GROUT
Permit Number - T06CM02334
Inspection Description - REINFORCED MASONRY PRE-GROUT
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
07/30/2007 | REINFORCED MASONRY PRE-GROUT | Approved | ||
02/07/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1) NORTH WALL: LINE A/2 TO A/4 AT 28'-10"-OK TO GROUT |
|
02/05/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1) NORTH ENTRY LENTIL TO 26 FEET-OK TO GROUT |
|
02/01/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1) TOP OUT GRID #4 A TO B+ AT 28/10 & 30 FT AND B TO D 2) TOP OUT GRID #5 A+ TO D+ AT 28/10 & 30 FT AND GRID A+, B, B+, C+ AND D+ AT GRID 4 TO 5 |
|
01/29/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* EXTERIOR WALLS F/5 TO B/1 @ 28'10" TOPPED OUT OK TO GROUT |
|
01/26/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* LINE F/3.5 TO F/5 @ 27'10" OK TO GROUT |
|
01/24/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 8" CMU WALL ON GRID LINE #1 FROM B TO H @ 26 FEET OK TO GROUT |
|
01/23/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 8" CMU WALLS @ RMS #201E, 211, 212, 213, 214, 215 & WING WALL @ GRID A - 4 TO 3 & GRID 4 A TO 10_8 ALL @ 24 FEET 8 INCH |
|
01/22/2007 | REINFORCED MASONRY PRE-GROUT | Denied | IVRS - Inspection : See detailed listing on site.| 999* NO ACCESS |
|
01/16/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* PER SHEET S2.1 8" CMU WALLS TO 24 FOOT 8 INCH ON SOUTHWEST END @ ROOMS #202, 201A, 219, 218, 217, 216 & WALL AT GRID LINE 4 - H TO G |
|
01/12/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* OK TO GROUT 12" CMU WALLS TO 20'8" AT SOUTHWEST CORNER FROM 3A TO D4-5 - ROOMS #111, 120, 101E, 112, 113 & 114 PER SHEET S2.1 |
|
01/10/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* EAST 12" CMU WALL FROM L-J GRID TO A-3 1/2 TO 20 FOOT 8 INCH |
|
01/09/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* SOUTH & SOUTHWEST CMU WALLS; J/2 TO G/4 @ 20'8" OK TO GROUT |
|
01/05/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* NORTHWEST CMU WALLS TO 16 FOOT 8 INCH CLASSROOM #110 N/W & WEST WALL, ROOMS #111, 120, 101E, 112, 113 & 114 - PER SHEET A101 |
|
01/03/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 16'8" EAST WALL |
|
01/02/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* CMU WALLS TO 16'8" FROM GRID F TO J AND #3 TO #5 ROOMS #102, 119, 101A, 118, 117, 116 & 115 -- OK TO GROUT |
|
12/29/2006 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1) EAST SIDE CMUN COLUMNS TO 13/4 AT GRID D-E-F |
|
12/13/2006 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* GRIDLINE A/2-2.5, 2/A-B, B/1-2 ALL THESE WALL IN COMPLIANCE WITH APPROVED PLAN AND SPECIFIC DETAIL ON SHEET S2.1 DETAILS ON SHEET S.4.0 8'8" TO 12'8" A.F.F.E GRIDLINE 1/C-H 10'-12'8" A.F.F.E |
|
12/05/2006 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* SOUTHWEST SECTION GRIDLINES 4-5 TO F TO H INTERIOR WALLS AT ROOMS 216, 217, 218 & 219 |
|
11/30/2006 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* NORTH QUAD A.5/4 TO D/4 @ 12'8"; A/2.5 TO B/1 @ 1ST LIFT @ 4'8" OK TO GROUT. |
|
11/29/2006 | REINFORCED MASONRY PRE-GROUT | Not ready for Inspection | IVRS - Inspection :* | |
11/24/2006 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* STEM LINE A-B/1-2.5 |
|
11/14/2006 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 3RD LIFT (12 FT. 8 INCH) SOUTH END FROM COLUMN LINE F TO G WEST SIDE. INCLUDING STAIRWELL SOUTH END FROM 4 TO 1 & EAST SIDE FROM J TO C -- OK TO GROUT ALSO, AT LINE D FROM 4 TO 5 -- TO 8 FOOT 8 INCH |
|
11/07/2006 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* NW QUADRANT - A/4 TO D/4, A/5 TO D/5 @ 12' LINE C/1 TO J/2 OK @ 12' TO POUR |
|
11/03/2006 | REINFORCED MASONRY PRE-GROUT | Partial Approval | 4' LINE 1/C-H 8' LINE 5/F-H.5 |
|
11/02/2006 | REINFORCED MASONRY PRE-GROUT | Denied | 1) REINFORCEMENT TO BE PLACED PER MSJC (AC1340) 2) SEE PLACEMENT SCHEDULE S-1.1 AND STAY WITHIN TOLERANCES |
|
10/19/2006 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* CORD BLDG; 2ND LIFT @ 5' LINES 3/5 TO LINES A TO J OK TO GROUT |
|
10/11/2006 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* CORE BLDG. MASONRY 1ST LIFT FROM COLUMN LINE 3/5 TO COLUMN LINES A TO J -- OK TO GROUT. |
|
10/05/2006 | REINFORCED MASONRY PRE-GROUT | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1ST LIFT AT SOUTH END GROUTED WITHOUT INSPECTION. |