Permit: T06CM02334

Parcel: 11107313A

Inspection Status: Approved

Inspection History: REINFORCED MASONRY PRE-GROUT

Permit Number - T06CM02334

Inspection Description - REINFORCED MASONRY PRE-GROUT

Inspection Status - Approved

Date Description Inspector Results Comments
07/30/2007 REINFORCED MASONRY PRE-GROUT Approved
02/07/2007 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1) NORTH WALL: LINE A/2 TO A/4 AT 28'-10"-OK TO GROUT
02/05/2007 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1) NORTH ENTRY LENTIL TO 26 FEET-OK TO GROUT
02/01/2007 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1) TOP OUT GRID #4 A TO B+ AT 28/10 & 30 FT AND B TO D
2) TOP OUT GRID #5 A+ TO D+ AT 28/10 & 30 FT AND GRID A+, B, B+, C+ AND D+ AT GRID 4 TO 5
01/29/2007 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
EXTERIOR WALLS F/5 TO B/1 @ 28'10"
TOPPED OUT
OK TO GROUT
01/26/2007 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
LINE F/3.5 TO F/5 @ 27'10" OK TO GROUT
01/24/2007 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
8" CMU WALL ON GRID LINE #1 FROM B TO H @ 26 FEET
OK TO GROUT
01/23/2007 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
8" CMU WALLS @ RMS #201E, 211, 212, 213, 214, 215 & WING WALL @ GRID A - 4 TO 3 & GRID 4 A TO 10_8 ALL @ 24 FEET 8 INCH
01/22/2007 REINFORCED MASONRY PRE-GROUT Denied IVRS - Inspection :
See detailed listing on site.| 999*
NO ACCESS
01/16/2007 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
PER SHEET S2.1
8" CMU WALLS TO 24 FOOT 8 INCH ON SOUTHWEST
END @ ROOMS
#202, 201A, 219, 218, 217, 216 & WALL AT GRID LINE 4 - H TO G
01/12/2007 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
OK TO GROUT
12" CMU WALLS TO 20'8" AT SOUTHWEST CORNER FROM 3A TO D4-5 - ROOMS #111, 120, 101E, 112, 113 & 114 PER SHEET S2.1
01/10/2007 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
EAST 12" CMU WALL FROM L-J GRID TO A-3 1/2 TO
20 FOOT 8 INCH
01/09/2007 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
SOUTH & SOUTHWEST CMU WALLS; J/2 TO G/4 @ 20'8"
OK TO GROUT
01/05/2007 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
NORTHWEST CMU WALLS TO 16 FOOT 8 INCH
CLASSROOM #110 N/W & WEST WALL, ROOMS #111, 120, 101E,
112, 113 & 114 - PER SHEET A101
01/03/2007 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
16'8" EAST WALL
01/02/2007 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
CMU WALLS TO 16'8" FROM GRID F TO J AND #3 TO #5
ROOMS #102, 119, 101A, 118, 117, 116 & 115 -- OK TO GROUT
12/29/2006 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1) EAST SIDE CMUN COLUMNS TO 13/4 AT GRID D-E-F
12/13/2006 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
GRIDLINE A/2-2.5, 2/A-B, B/1-2 ALL THESE WALL IN COMPLIANCE WITH APPROVED PLAN AND SPECIFIC DETAIL ON SHEET S2.1 DETAILS ON SHEET S.4.0 8'8" TO 12'8" A.F.F.E

GRIDLINE 1/C-H 10'-12'8" A.F.F.E
12/05/2006 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
SOUTHWEST SECTION GRIDLINES 4-5 TO F TO H
INTERIOR WALLS AT ROOMS 216, 217, 218 & 219
11/30/2006 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
NORTH QUAD A.5/4 TO D/4 @ 12'8"; A/2.5 TO B/1 @ 1ST LIFT @ 4'8" OK TO GROUT.
11/29/2006 REINFORCED MASONRY PRE-GROUT Not ready for Inspection IVRS - Inspection :*
11/24/2006 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
STEM LINE A-B/1-2.5
11/14/2006 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
3RD LIFT (12 FT. 8 INCH) SOUTH END FROM COLUMN
LINE F TO G WEST SIDE.
INCLUDING STAIRWELL SOUTH END FROM 4 TO 1 & EAST SIDE
FROM J TO C -- OK TO GROUT
ALSO, AT LINE D FROM 4 TO 5 -- TO 8 FOOT 8 INCH
11/07/2006 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
NW QUADRANT - A/4 TO D/4, A/5 TO D/5 @ 12' LINE C/1 TO J/2
OK @ 12' TO POUR
11/03/2006 REINFORCED MASONRY PRE-GROUT Partial Approval 4' LINE 1/C-H
8' LINE 5/F-H.5
11/02/2006 REINFORCED MASONRY PRE-GROUT Denied 1) REINFORCEMENT TO BE PLACED PER MSJC (AC1340)
2) SEE PLACEMENT SCHEDULE S-1.1 AND STAY WITHIN TOLERANCES
10/19/2006 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
CORD BLDG; 2ND LIFT @ 5' LINES 3/5 TO LINES A TO J
OK TO GROUT
10/11/2006 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
CORE BLDG. MASONRY 1ST LIFT FROM COLUMN LINE 3/5 TO COLUMN LINES A TO J -- OK TO GROUT.
10/05/2006 REINFORCED MASONRY PRE-GROUT Denied IVRS - Inspection :
See detailed listing on site.| 999*
1ST LIFT AT SOUTH END GROUTED WITHOUT INSPECTION.