Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T06CM02325

Parcel: 117091340


Addresses:

1127 S 8TH AV #02

Inspection Status: Approved

Inspection History: PLUMBING - GAS PRESSURE TEST

Date Description Inspector Results Comments
04/26/2006 PLUMBING - GAS PRESSURE TEST Approved IVRS - Inspection :*
PRESSURE TEST OK
03090 - PROVIDE ACCESS TO STOVE AND FURNACE LOCATED INSIDE.
PROVIDE ELECTRICAL BONDING OF GAS LINE
RECALL FOR FINAL INSPECTION, LEAVE KEY OR CONTACT NUMBER FOR ACCESS.
04/25/2006 PLUMBING - GAS PRESSURE TEST Not ready for Inspection IVRS - Inspection :*